AWE Torque Wrench with Angle Digital Display

$
2,180.00-6,000.00
Model:
AWE
inquiry
AWE Torque Wrench with Angle Digital Display
AWE Torque Wrench with Angle Digital Display AWE Torque Wrench with Angle Digital Display AWE Torque Wrench with Angle Digital Display AWE Torque Wrench with Angle Digital Display AWE Torque Wrench with Angle Digital Display AWE Torque Wrench with Angle Digital Display

AWEWith angleTorque wrenchuseExplanation书

1,System Overview

1.1Main purpose and scope of application

AWE Torque Wrench with Angle Digital Display is a new type of digital display wrench. Can directly and accurately read the torque-angle value, simple to use,Easy to operate. Suitable for bolt fastening and control in the automotive industry, machinery industry, etc.。

1.2 Features

1.2.1 Can directly read the torque-angle value;

1.2.2± 1 ° (rotate 90 ° at 30 ° / sec);

1.2.3 ± 1%;

1.2.4 Can measure clockwise and counterclockwise;

1.2.5 The buzzer, LED and vibrator prompt the target value;

1.2.6Four torque units: N.m, kfg.cm, ft.lbf, in.lbf, etc.

1.2.7Angle unit is degree (°)

1.2.8Comes with 3.7V lithium battery, you can directly charge the lithium battery through USB;

1.2.9Comes with usb interface, you can upload and save data.

1.2.10Measurement mode: three measurement modes: real-time mode, peak mode and preset mode.

1.2.11Automatic backlight function;

1.3 Specifications

model

Without communication

AWE2 -0010

AWE2 -0030

AWE3-0030

AWE3-0060

AWE3-0085

AWE3 -0135

AWE4 -0135

AWE4 -0200

AWE4 -0340

AWE6-

0500

AWE6-

0850

With communication

AWE2 -0010R

AWE2 -0030R

AWE3-0030R

AWE3-0060R

AWE3-0085R

AWE3 -0135R

AWE4 -0135R

R

AWE4 -0200R

AWE4 -0340R

AWE6-

0500R

AWE6-

0850R

Minimum division value

0.01

0.1

Maximum operating range

(N.m)

10N.m / 7.37ft.lb / 88.50in.lb / 101.97kgf.cm

30N.m / 22.12ft.lb / 265.5in.lb / 305.91kgf.cm

30N.m / 22.12ft.lb / 265.5in.lb / 305.91kgf.cm

60N.m / 44.25ft.lb / 531.04in.lb / 611.82kgf.cm

85N.m / 62.69ft.lb / 752.31in.lb / 866.75kgf.cm

135N.m / 99.57ft.lb / 1195in.lb / 1376.61kgf.cm

135N.m / 99.57ft.lb / 1195in.lb / 1376.61kgf.cm

200N.m / 147.5ft.lb / 1770in.lb / 2039.43kgf.cm

340N.m / 250ft.lb / 3009in.lb / 3467.03kgf.cm

500N.m / 4424in.lb / 368.7ft.lb / 5098.58kgf.cm

850N.m / 7521in.lb / 626.8ft.ln / 8667.58kgf.cm

Connector (inches)

1/4

3/8

1/2

3/4

length

390

420

535

655

   

TorqueAccuracy * 1

± 1%

 

Angle accuracy

± 1 ° (Accuracy of angle measurement at a speed of 30 ° per second to 90 °)

Data storage capacity

255

Operating mode

Peakmode(P) / Real-time mode (T)/ Preset mode (Pre)

unit

N.m, kgf.cm, ft.lbf, in.lbf

Ratchet head form

Two-way ratchet head

Ratchet head teeth

36

48

Number of keys

5

battery

3.7V lithiumbattery

Operating temperature

-10 ℃ ~ 60 ℃

storage temperature

-20 ℃ ~ 70 ℃

humidity

90% without condensation

Drop test height

1 meter

Vibration test conditions * 2

10G

Life test * 3

10000 times

2. Product components

2.1 Product structure

2.2LCD display

1,Two-way ratchet head2,Steering paddle

3. LED indicator 4.LCD screen

%1,Button 6.buzzer

7. Battery box 8. Battery cover

9,Ratchet torque square head10. USB / charging interface

11. Charging indicator 12. Grip

13. Battery power display 14. Angle value display

15. Working mode 16. Unit display

17. Torque direction 18. Torque value display

19. Up / Preset value unlock button 20. Store / View button

21. Down / working mode switching button 22. Unit switching / menu button

23. Power / zero button

three,jobsMode description

3.1jobsMode switch

3.2Real-time modeoperating

The real-time measurement mode follows the applied torque value and the rotation angle value (when the rotation angle value is greater than 0, the selected angle is calculated) When unloading torque,Torque value to zero, The angle is automatically cleared.

When the LCD shows T,forIn real-time mode, if T is not displayed, press \"\"Key to switch the mode. The operation steps are shown in the following figure:

NOTE1: In real-time mode, when the torque value is greater than 0, the angle value will be displayed.

NOTE2:In real-time mode, when the preset target force value reaches 90%, the red light flashes after the buzzer is turned on, and the buzzer shortly sounds; after the vibrator is turned on, the red light flashes, the vibrator vibrates intermittently, and the vibration frequencyaccording toTorqueProximity increases vibration frequency

NOTE3:In real-time mode, after the buzzer is turned on, themore than theWhen the target torque value is preset, the red light is on and the buzzer is on; after the vibrator is turned on, the red light is on and the vibrator vibrates continuously.

NOTE4: The buzzer and vibrator cannot be enabled at the same time. If the user turns on the buzzer, the vibrator turns off automatically; if it turns on, the buzzer turns off automatically.

3.3Peak mode

In peak measurement mode, when torque is applied, the wrench will lock the maximum applied torque and maximum angle, and will其Displayed on the LCD screen. When unloading torque, peak torqueAnd peak angleWill be locked and the LCD screen will be loaded when loaded againLocked peaks will not be updated. When the automatic save function is turned on, the wrench will automatically save the force value and angle, and automatically clear it.需get onIn the next measurement, load torque directly. When the auto save function is not enabled, it can be saved by pressing \"M \" or cleared by pressing \"P / C \".

The LCD screen displays P as the peak mode. If P is not displayed, press\"\"键To switch.The operation steps of peak mode are shown in the figure below:

NOTE1: In peak mode, when the torque value is greater than 0 during the first measurement, the wrench displays the angle and torque value; but when the force is applied (when the value is not cleared and the value is not saved), the torque value measured this time is greater than the first measurement The angle value will follow the torque value when the force value changes.

NOTE2: In peak mode, when 90% of the preset target torque value is reached, the red light blinks after the buzzer is turned on, and the buzzer sounds shortly; after the vibrator is turned on, the red light blinks and the vibrator vibrates intermittently.

NOTE3: In real-time mode, after the buzzer is turned on, when the preset target torque value is reached, the red light is on and the buzzer is on; after the vibrator is turned on, the red light is on and the vibrator vibrates continuously.

NOTE4: The buzzer and vibrator cannot be enabled at the same time. If the user turns on the buzzer, the vibrator turns off automatically; if it turns on, the buzzer turns off automatically.

3.4Preset mode

The preset mode is adopted扭After the force value reaches the target value, continue to design the screw to be locked at a certain angle. When the applied torque value is greater than or equal to the target torque值, The wrench starts to calculate the angle value. When the torque is unloaded, the torque and angle values ​​are automatically locked.

LCD displayPrePreset mode, if not displayedPre,Press\"\"键To switch.The operation steps of preset mode are shown in the figure below:

NOTE1: In preset mode, the wrench will only display the angle when the preset target torque value is reached.

NOTE2: In the preset mode, when the preset target torque value reaches 90%, the red light flashes.

NOTE3: In preset mode, after the buzzer is turned on, when the preset target torque value is reached, the red light is on and the buzzer is short; after the vibrator is turned on, the red light is on and the vibrator vibrates continuously.

NOTE4: The buzzer and vibrator cannot be enabled at the same time. If the user turns on the buzzer, the vibrator turns off automatically; if it turns on, the buzzer turns off automatically.

4. How to use

4.1 Switch on

短press\"P / C\"keyBootAfter the start, if the power display is insufficient, it will automatically shut down and can be used normally after charging.

4.2 Unit switching

4.3 Setting preset values

Press \"firstP / C\"Key to boot, press \"\"Key to determine whether the key lock is turned on. If the key lock is turned on, you can turn off the key lock function through \" key lock \"in the system settings (see \" System Settings \"below). Open, it will display the letter \"\", Then you can press \"\"Key to increase the target value, or press \"\"Key to decrease the target value. After setting, press \" U / S \"key to save and exit.

4.4Clear

①When the wrench force value is 0, press \"P / C\"Key will display \"\", It means that the angle calibration is cleared.在When the angle is cleared, please place the wrench on a flat surface to rest,untilAngle reset completed。

②When the force value of the wrench is displayed, press \"P / C\"keyDirectly reset the force value, The angle is not clear。

4.5Data saving and viewing

4.5.1 Data storage

①Short press on the measurement interface \"M\"Key, display \"\", Means that the save is successful.当When the force value is zero, it cannot be saved, it will prompt\"\"。

②Auto save: In peak mode and preset mode, when the auto save time is not set to 0 in the system settings, the wrench will automatically save the torque value. When the auto-save time is 0, the wrench will not automatically save the torque value, the user needs to manually press \"M \" to save the torque value.

4.5.2 View saved data

Press \"P / C \" key to boot orUnder the boot measurement interface, Long press \"M \" key, you can view the saved data, inData viewing interface canby,\"\"or\"\"key,View saved records whenAfter viewing, press \"U / S\"Key to exit。

4.6 Delete stored data

①In the measurement interface, long press \"M\"Key, after entering the data view interface, short press \"P / C\"Key, display \"\",或\"\",whendisplay\"\",thenPress \"U / S \" to display \"\",That means all data is deleted (the instrument cannot delete data one by one).

② On the measurement interface, long press \"M\"Key, after entering the data view interface, press \"P / C\"Key, display \"\", Continue to press \"P / C\"Key, switch display \"\", Then press \" U / S \"to return directly to the measurement interface, indicating that the data will not be deleted.

4.7System settings

4.7.1 Angle setting: the setting range is 0 ~ 999, the user can press \"\"Key and \"\"Key to set the desired value.Current angledisplay999 hours, Adding up will cycle into0,Also when the angle is displayed0 is,press\"\"Key downMinus time, angleWill jump to 999.

4.7.2 Key lock: for preset target torque value. Users can press \"\"Key and \"\"Key to set the key lock on or off, \" 1 \"is on, \" 0 \"is off.

4.7.3 Auto save time: the settable range is 0 ~ 5 (seconds), 0 means turn off the auto save function. Users can press \"\"Key and \"\"Key to set the automatic save time.

4.7.4 Buzzer: Set the buzzer on or off. 1 is on, 0 is off. Users can press \"\"Key and \"\"Key to set buzzer on or off.

4.7.5 Vibrator: Set the vibrator on or off. 1 is on, 0 is off. Users can press \"\"Key and \"\"Key to set the vibrator on or off.

4.7.6 Auto power off: Auto power off time setting, the setting range is 0 ~ 30 (minutes). 0 is to turn off the automatic shutdown function, the user can press \"\"Key and \"\"Key to set the automatic shutdown time you need.

4.7.7 Restore factory settings: Users can restore the instrument to factory settings through this function. By pressing \"\"Key and \"\"Key to select \"\"(Restore factory settings) or \"\"(Do not restore factory settings). If you choose to restore factory settings, choose \"\"After quickly pressing the \" U / S \"key, the LCD screen will appear \"\"(The factory settings have been restored), and the system automatically returns to the measurement interface. If you choose not to restore the factory settings, select \"\"Just.

5. Communication and uploading data

This wrench adopts USB communication mode, which can save the saved data上When it is transferred to a PC, the real-time measurement data can also be uploaded to the PC.

Use the CD provided by the manufacturer, install the communication software on the computer, and then connect the digital display wrench to the computer with the data cable when the digital display wrench is turned on. Double-click the software icon to open the software. \", Then click \" Part Open \", and then click \" Upload \", then the stored data in the instrument will appear on the table, indicating that the host computer has been successfully connected and the purpose of reading the stored data has been achieved. As shown below:

Communication settings: baud rate 4800, 8 data bits, no parity, 1 stop bit.

Communication format:

3 bytes data header + 1 byte function code + 2 bytes data length + N bytes data length + 1 byte checksum

Data header: 0xEB 0x00 0x55

function code

meaning

example

F0

PC sends a handshake command to the wrench

Instruction: EB 00 55 f0 00 00 30

F1

Wrench handshake confirmation command to PC

Return instruction: EB 00 55 F1 00 00 62

F5

The PC requests the wrench to store data

Instruction: EB 00 55 f5 00 00 35

01

Spanner sends span data

Return instruction: EB 00 55 01 00 02 00 1E C2

02

Wrench send storage data size

Return instruction: EB 00 55 02 00 02 00 06 94

03

Wrench send storage data size

Return instruction: EB 00 55 03 00 12 00 01 00 00 00 04 00 00 00 00 00 02 00 00 00 00 00 00 B8

04

Wrench sending data has been sent

Return instruction: EB 00 55 04 00 00 88

FC

PC requests real-time data

Instruction: EB 00 55 FC 00 00 3C

Seven, prompt information

Prompt message

meaning

Solution

ER-2

Abnormal memory

The memory is full, or the memory is damaged. Clear stored data or return to factory for repair.

ER-3

Abnormal sensor or circuit board

The force value is greater than 5% and the zero point is cleared, and the unloading force value is then reset.

If the unloading force value cannot clear the error message, return to the factory for repair.

ER-4

Overrange

exceed满Range120% will prompt ER-4, after unloading force value, press 【P / C] Key to clear the error.

SUCC

prompt操Done

After an operation is completed, it returns automatically.

Fail

Prompt operation failed

An operation fails and returns automatically.

八, Maintenance and storage

8.1 note:

In order to maintain good accuracy, it is recommended to recalibrate once every year.

8.2 Excessive torque may cause damage or loss of accuracy (more than 105% of the maximum torque range).

8.3 Do not shake the wrench violently or drop the wrench on the ground.

8.4 Do not use the wrench as a hammer.

8.5 Do not place the wrench in high temperature, high humidity or direct sunlight.

8.6 Do not use wrenches near water.

8.7 If you accidentally get the wrench wet, wipe it dry with a dry towel immediately. Salt in the sea water may damage the wrench.

8.8 Do not use organic solvents to clean the wrench, such as alcohol or paint thinner.

8.9 Do not put the wrench near magnetic objects.

8.10 Do not place the wrench in a place where there is a lot of dust or sand. This will cause serious damage to the wrench.

8.11 Do not stress the LCD screen.

九, Random accessories

1

lithium battery

1节

2

Instructions

1 serving

3

Battery cover key

1

4

Certificate of conformity

1 serving

5

Warranty Card

1 serving

6

Inspection certificate

1 serving

7

Desiccant

1 package

Feedback