I. Overview

1.1Main purpose and scope of application

AWJRatchet headDigital displayTorque wrench和AWJCInterchangeable head digital display wrenchDifferent from ordinary torque wrenches,among themAWJCInterchangeable head wrenchIts own ratchet head canrandomReplace with plugs such as open head, plum head, movable open head, etc.Use bothIt has powerful operation functions, including torque setting; unit setting; mode setting; value storage; value clearing; value output and user correction function. Easy to operate, by installing digital displayScreen downRequirements for the operator. It is suitable for bolt tightening and control in automobile industry and machinery industry.

1.2Features

1.2.1Digital display torque reading

1.2.2Clockwise ±2%, Counterclockwise ±2.5%Accuracy (of the MAX operating range20 ~ 100%)

1.2.3Can operate clockwise and counterclockwise

1.2.4Peak hold and real-time mode

1.2.5Buzzer andLCDIndication (when the predetermined torque value is reached)

1.2.6Four engineering units (ft.lb、in.lb、N.m、kgf.cm)

1.2.799组Recordable value can be stored

1.2.8 5Automatic shutdown in minutes

1.3Product model selection

①: Accuracy

Accuracy

±2%-Clockwise/±2.5%-Counterclockwise

②: Whether with communication function

Communication transmission function

   

1.4各Component functions and names

1, Two-way ratchet head 11, Torque value

2、Steering paddle12、P(Peak mode),T(Real-time mode)

3、main body 13,unit(N.m、in.lb、ft.lb、kgf.cm)

4、LCDscreen14、ledIndicator light

5,button15, Menu button

6,buzzer16, OK button

7,Battery case 17, Up button

8,battery cover 18, Cancel button

9, Ratchet torque square head 19, Down button

10, Grip

二, Product technical specifications

model

AWJ2- 0010

AWJ2- 0030

AWJ3-

0030

AWJ3-

0060

AWJ3-

0085

AWJ3- 0135

AWJ4- 0135

AWJ4-0200

AWJ4-

0340

AWJ6-

0500

AWJ6-

0850

AWJC1

-010

AWJC1 -030A

AWJC1 -030B

AWJC1

-060

AWJC1

-085

AWJC1 -135

AWJC2 -135

AWJC2 -200

AWJC2 -340

   

MIN index value

0.01

0.1

MAX operating range

(N.m)

10N.m / 7.37ft.lb / 88.50in.lb / 101.97kgf.cm

30N.m / 22.12ft.lb / 265.5in.lb / 305.91kgf.cm

30N.m / 22.12ft.lb / 265.5in.lb / 305.91kgf.cm

60N.m / 44.25ft.lb / 531.04in.lb / 611.82kgf.cm

85N.m / 62.69ft.lb / 752.31in.lb / 866.75kgf.cm

135N.m / 99.57ft.lb / 1195in.lb / 1376.61kgf.cm

135N.m / 99.57ft.lb / 1195in.lb / 1376.61kgf.cm

200N.m / 147.5ft.lb / 1770in.lb / 2039.43kgf.cm

340N.m / 250ft.lb / 3009in.lb / 3467.03kgf.cm

500N.m / 4424in.lb / 368.7ft.lb / 5098.58kgf.cm

850N.m / 7521in.lb / 626.8ft.ln / 8667.58kgf.cm

Connector(inches)

1/4

3/8

1/2

3/4

Interchangeable head connection size

9 * 12

14 * 18

 

Buzzer setting range (N.m)

0.5 ~ 10

1.5 ~ 30

1.5 ~ 30

3 ~ 60

4.25 ~

85

6.75 ~

135

6.75 ~ 135

10 ~

200

17 ~ 340

25 ~ 500

42.5 ~

850

length

390

420

535

655

950

1220

Accuracy*1

Clockwise: ±2%

Counterclockwise: ±2.5%

Clockwise: ±2.5%

Counterclockwise: ±3.5%

Data storage capacity

100

Operating mode

Peak holdP)/Real-time mode (T)

unit

N.m、in.lb、ft.lb、kgf.cm

ratchetHead form

Two-way ratchet head

Ratchet head teeth

36

48

Number of keys

5

battery

2节1.5V 5Size battery

Operating temperature

-10℃~ 60℃

storage temperature

-20℃~ 70℃

humidity

No condensation90%

Drop test height

1米

Vibration test conditions*2

10G

life span test* 3

10000次

3. How to use

3.1、Zero switch:Press the C button to boot, if there is a force value after the boot, you can press the C button to clear it, enter the sleep mode for 5 minutes without operation, press the C button to start, and also choose to press the C button to shut down.

3.2、Preset value setting method:Under normal power-on state, short press the M key on the measurement interface, and use the up and down keys to switch the preset value you need. After setting the preset value, the system will automatically save the preset value. Press the M key continuously until you return to the measurement interface.

3.3Real-time and peak mode setting method:The default real-time mode T of this product is turned on. If you want to switch the peak mode P, you need to press the M key twice in the measurement interface, NODE appears, and then you can choose the TP switching mode through the up and down keys. After the selection is completed, press the M key continuously until you return to the measurement interface That's it.

3.4、Unit mode setting method:This product hasN.m、in.lb、ft.lb、kgf.cmFour unit mode selection, can be switched according to actual use. Setting method in measurementShort press the interface three timesM键,appearUNLT,Then you can use the up and down keys to select the unit mode you need. After the selection is complete, press the M key continuously until you return to the measurement interface.

3.5、Data storage and viewing method:Data saving. In the P peak mode, the measured data can be saved directly by pressing the C key. Press the OK key to save. After saving, it will automatically return to the measurement interface to test again. In this cycle, the data can be saved in 99 groups The numbers are 001.002 ..... 099).

View data. Short press M key 4 on the measurement interface to view the saved data group (display 0000 when there is no data saved). You can view the data number by pressing the up and down keys. No detailed display of the force value stored by the number is displayed in two seconds. Then press the M key continuously until you return to the measurement interface.

3.6、Clear data storage value:Short press M key 5 on the measurement interface, CLR appears, then press C key to display NO? Then press C key to confirm and clear, and display DEL to return to the measurement interface directly after completion (If you press the M key on the NO? Interface, you will give up deleting and return to the measurement interface. Note: Clearing the data is done all at once, so there is no single operation)

four,notematter:

4.1 In order to maintain good accuracy, it is recommended to recalibrate once every year.

4.2、 Over-torque may cause damage or loss of accuracy (more than MAX torque range105%).

4.33. Do not shake the wrench violently or drop the wrench on the ground.

4.41. Do not use the wrench as a hammer.

4.52. Do not place the wrench in a place with high temperature, high humidity or direct sunlight.

4.61. Do not use a wrench near water.

4.7If you accidentally get the wrench wet, please wipe it dry with a dry towel immediately. Salt in the sea water may damage the wrench.

4.81. Do not use organic solvents to clean the wrench, such as alcohol or paint thinner.

4.93. Do not put the wrench near magnetic objects.

4.102. Do not place the wrench in a place where there is a lot of dust or sand. This will cause serious damage to the wrench.

4.11, Do not pressLCDscreen.

五、 Battery disposal

5.12. If the torque wrench is not used for a long time, please remove the battery.

5.21. When you need to travel long distances or in cold areas, please prepare spare batteries.

5.31. Do not mix batteries of different brands, and do not mix old and new batteries.

5.4, Sweat, oil, etc. will hinder the contact of the battery electrode, please wipe the battery clean before putting in the torque wrench.

5.53. Please discard the used batteries in the designated recycling place.Do not put the battery into fire.

六, Schedule of random attachments

1

Desiccant

1包

2

5Vbattery

1对

3

Battery box key

1把

4

Instructions

1份

5

Certificate of conformity+Warranty Card

1份

Note:AWJ与AWJCUnified packaging accessories